Data Center Cooling Systems

Data Center Cooling Systems for High-Density Computing Facilities

Our integrated data center cooling solutions cover central chiller plants, containerized cooling plants, precision server cooling, server room air conditioning, and liquid cooling solutions. With water-cooled, air-cooled, dual-cool source, and liquid cooling configurations available, the system architecture can be selected according to facility scale, rack heat load, water availability, site conditions, and cooling continuity requirements.

 
 

Integrated Cooling Configurations for Data Centers

The Data Center Air Conditioning System integrates the cooling source and terminal equipment into a building-level cooling solution.

The central chiller plant can include:

  • Water-cooled or air-cooled chillers
  • Cooling towers
  • Circulation pumps
  • Plate heat exchangers
  • Air handling units (AHUs)
  • Precision air conditioners
  • Intelligent group control systems

Chilled water is distributed from the central plant to terminal equipment throughout the facility. Precision air conditioners and AHUs can be selected according to room layout and airflow requirements.

Three cooling source configurations are available:

Cooling configuration Main equipment Selection conditions
Water-cooled Water-cooled chillers and cooling towers Water-rich locations and projects targeting high overall cooling efficiency
Air-cooled Air-cooled chillers Water-scarce locations and small to medium facilities
Dual cool source Air-cooled and water-cooled systems Mission-critical facilities requiring independent backup cooling sources

Containerized Chiller Plant Capacity and Configuration

The Containerized Chiller Plant integrates chillers, pumps, cooling towers, piping, valves, and intelligent controls into a prefabricated container structure.

Its published configuration references include:

Selection item Available configuration
Single-container cooling capacity 100–2,200 RT
Multi-container cooling capacity 4,000 RT and above
Cooling source Air-cooled / Water-cooled / Dual Cool Source
Compressor type Screw / Centrifugal / Magnetic Bearing Centrifugal
Container arrangement Single-container / Multi-container
Redundancy N+1 configuration
Ambient temperature range -30℃ to +50℃
Deployment Outdoor / Rooftop / Available open space

The plant is factory-prefabricated and pre-commissioned. Chillers, pumps, cooling towers, internal piping, electrical connections, and controls are assembled and validated before shipment. On-site work includes positioning, power connection, and water supply and return piping connections.

The modular configuration supports additional container deployment as cooling demand increases. A dedicated conventional equipment room is not required.

The stated capacity ranges are references. Final capacity and configuration depend on project requirements and equipment selection.

Precision Cooling for Data Centers: Server Rows and Localized Hot Spots

The Server Cooling System uses in-row air conditioners installed between server racks. Front air supply and rear air return create short airflow paths close to the heat sources.

Available configurations include:

  • Chilled water or air-cooled direct expansion cooling
  • Upflow or downflow airflow
  • Optional AC or EC fans
  • Optional dual power input (ATS)

The system automatically adjusts cooling output according to actual rack heat loads.

Group control supports up to 64 units, including scheduled rotation, fault-based rotation, cascading, demand synchronization, and centralized monitoring. BMS compatibility and configurable communication protocols are also available.

Server Room Cooling Specifications

The Server Room Cooling System is designed for small to medium-sized server rooms, network rooms, and critical equipment spaces.

Selection item Published specification
Temperature control accuracy ±1℃
Humidity control accuracy ±5%
Sensible heat ratio SHR ≥0.9
Sensible cooling energy share Over 95%
Cooling technology Air-Cooled Direct Expansion (CRAC) / Chilled Water (CRAH)
Airflow Upflow / Downflow
Load adjustment 10%–100% stepless capacity adjustment
Group control Up to 64 units
EC fans Optional

The system supports variable-speed compressors, electronic expansion valves, and optional EC fans. Its control platform monitors voltage, frequency, cooling capacity, airflow, and temperature and humidity trends.

Liquid Cooling for AI Data Centers and HPC Facilities

Liquid Cooling Solutions use direct-contact immersion cooling to remove heat from server components, including CPUs and GPUs.

The published product specifications include:

  • Rack power density support beyond 20 kW per rack
  • System PUE can be below 1.1
  • Real-time coolant temperature, flow rate, and pressure monitoring
  • Remote monitoring and centralized management
  • Configurable communication protocols for BMS integration
  • Coordination with air cooling systems for hybrid air-liquid cooling

The solution is intended for AI training clusters, GPU computing clusters, HPC facilities, and hyperscale AI data centers. It can also be considered for projects requiring liquid and air cooling coordination.

Project Configuration and Technical Coordination

Cooling system configuration depends on the facility's cooling load, cooling source conditions, available installation space, climate, and required operating reliability.

The available system configurations include central chiller plants, containerized chiller plants, precision server cooling, server room cooling, and liquid cooling.

Project-specific equipment selection and integration can be developed around these requirements. Final equipment combinations, capacities, control interfaces, and redundancy arrangements are subject to project evaluation.

Request a Data Center Cooling System Quotation

Send us your project cooling load, rack power density, facility location, preferred cooling source, equipment layout, or preliminary technical specifications.

We can use the available project information to discuss suitable data center cooling configurations and prepare a project-specific quotation.

As one of the most professional data center cooling systems manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. If you're going to buy customized data center cooling systems made in China, welcome to get quotation from our factory. For price consultation, contact us.

data center cooling systems, integrated cooling system, Liquid Cooling Solutions

whatsapp

Phone

E-mail

Inquiry

Bag